Connecting to MNIS in LCP
Prerequisites§
-
Obtain the MNIS host IP address with respect to SmartPTT server.
Tip
Basically, MNIS is installed to the same host as SmartPTT server.
-
From the MNIS Configuration Utility, obtain the following information:
- MNIS Application ID.
- TCP port of the MNIS control interface.
- MNIS ports used for different types of data.
Procedure§
-
In the Configurator, on the Systems tab, expand NAI Systems → <name of the LCP system>, and then click MNIS Settings.
MNIS settings appear in the right pane.
-
Set up MNIS connection:
- From the Socket Type list select TCP.
-
In the MNIS Service Address field, enter the MNIS host address and TCP port.
Example
192.168.27.5:55000localhost:55000 -
Click Test to ensure MNIS availability.
-
In the MNIS ID field, enter the MNIS Application ID.
- Set up port numbers delivered in MNIS packets
to identify data types (GPS, TMS etc.):
- In the Location Service (LRRP) field, enter the MNIS port number that is set for GPS service using LRRP.
- In the Location Service (LIP) field, enter the MNIS port number that is set for GPS service using LIP.
- In the Text Message Service field, enter the MNIS port number that is set for TMS service.
- In the Telemetry Service field, enter the MNIS port number that is set for telemetry service.
- In the bottom part of the Configurator, click Save to save changes.
- To apply changes, click Restart in the bottom part of the Configurator.