Selecting Voice Call Interface in LCP
Prerequisites§
- From LCP radio configurations, learn durations of group call hangtime and individual call hangtime.
- From LCP repeater configurations, learn repeater preamble durations.
- Connect to the LCP main repeater.
Procedure§
-
In the Configurator, on the Systems tab, expand NAI Systems, and then click the required node.
Basic connection settings appear.

-
From the Voice and radio commands list, select one of the following options:
- If you have SmartPTT Enterprise, select Transmit via hybrid interface.
- If you have SmartPTT PLUS, select Transmit via two-way NAI voice.
-
In the bottom part of the Configurator, click Save to save changes.